Facebook
  • 3-6KW Single-phase MPPT Hybrid Inverter
  • 3-6KW Single-phase MPPT Hybrid Inverter
  • 3-6KW Single-phase MPPT Hybrid Inverter
  • 3-6KW Single-phase MPPT Hybrid Inverter
  • 3-6KW Single-phase MPPT Hybrid Inverter
  • 3-6KW Single-phase MPPT Hybrid Inverter
  • 3-6KW Single-phase MPPT Hybrid Inverter
  • 3-6KW Single-phase MPPT Hybrid Inverter

3-6KW Single-phase MPPT Hybrid Inverter

No.3-6KW Single-phase
3-6KW Single-phase MPPT Hybrid Inverter; 2/1 MPPT; Support multi-parallel connection; Support flexible access of diesel generator; Compatible with lead-acid and lithium-ion battery; Support intelligent EMS management function;
  • 3-6KW Single-phase MPPT Hybrid Inverter
  • 3-6KW Single-phase MPPT Hybrid Inverter
  • 3-6KW Single-phase MPPT Hybrid Inverter
  • 3-6KW Single-phase MPPT Hybrid Inverter

Description

3-6KW Single-phase MPPT Hybrid Inverter

Product Features:
Safe & Reliable
Passed IEC/EN62109-1/-2, IEC/EN62477-1, South Africa NRS097-2-1:2017, IEC/EN61000-6-1, IEC/EN61000-6-3 test certification; 

Friendly & Flexible
Support multi-parallel connection;
Support flexible access of diesel generator;
Compatible with lead-acid and lithium-ion battery; 

Economical & Practica
Support intelligent EMS management function;
Support on/off-grid automatic switching function to ensure uninterrupted power when important loads are off-grid;

Technical Specification:
Technical specification R3KL1 R3K6L1 R4KL1 R4K6L1 R5KL1 R6KL1
Input (PV)  
Max. power(kW) 4.6 6 7
Max. DC voltage(V) 550
MPPT voltage range(V) 125~500
Max.input current of single MPPT(A) 14
MPPT tracker/strings 2/1
AC output  
Rated output power(kVA) 3 3.68 4 4.6 5 6
Max. output current(A) 13 16 17.4 20 21.7 26
Grid voltage/range(V) 230/176~270
Frequency (Hz) 50 /60
PF  0.8 lagging-0.8 leading
THDi <3%
AC output topology L+N+PE
Battery Data  
Battery voltage range(V) 40-58
Max. charging voltage(V) 58
Max. charge/discharge current(A) 95/62.2 95/75 95/83.3 95/95.8 95/104.2 95/110
Battery type Lithium /Lead-acid
Communication interface CAN/RS485
EPS output      
Rated power (kVA) 3 3.68 4 4.6 5 6
Rated output voltage(V)   230
Rated output current(A) 13 16 17.4 20 21.7 26
Rated frequency (Hz) 50 /60
Automatic switching time (ms) <20
THDu <2%
Overload capacity 110%, 30S/120%, 10S/150%, 0.02S
General Data  
Battery chage/dischage efficiency 95.00%
DC Max. efficiency 97.60%
Europe efficiency 97.00%
MPPT efficiency 99.90%
Ingress protection IP65
Noise emission (dB) <35
Operation temperature - 25℃~ 60℃
Cooling Natural
Relative humidity 0  ~95%(non-condensing)
Altitude 2,000m(>2,000 Derating)
Dimensions W*D*H (mm) 550*200*515
Weight (kg) 25
Isolation transformer No
Self-consumption(W) <3
Display and communication  
Display LCD
Interface:RS485/Wifi/4G/ CAN/DRM Yes/ Opt/ Opt/ Yes/ Yes
Safety standard IEC/EN62109-1/-2,  IEC/EN62477-1
EMC IEC/EN 61000-6-1, IEC/EN 61000-6-3
On-grid South Africa NRS097-2-1:2017, UK G98,G99

Download